Gate Role Center content by permission with AccessByPermission
Description
A page of type RoleCenter cannot have triggers (AL0378, error) or procedures (AL0569, warning that will become an error), and the AL compiler applies both rules to a pageextension whose target is a Role Center. That removes the usual way to show a control conditionally: compute a global Boolean in OnOpenPage and bind Visible to it. An easy-looking remediation of AL0378 is to delete the trigger and bind Visible or Enabled directly to a local procedure such as CanSeeMyCustomers(). That still builds, but with two future errors: AL0573 for the procedure call in a client expression and AL0569 for the procedure itself. Neither message names the alternative.
When the condition is "the user has permission to this object", the declarative alternative is the AccessByPermission property on the part, action, or field. It takes TableData <table> = R|I|M|D (any combination; having any one of the listed permissions is enough) or X for Table, Page, Report, Codeunit, XmlPort, or Query. Its applies-to list covers page fields, parts, system parts, chart parts, actions, and whole pages and reports; it does not include groups or cue groups. The element is removed for users without the permission, not disabled. That per-user removal requires the UI Elements Removal setting LicenseFileAndUserPermissions; under LicenseFile removal follows the license, not the user's permission sets.
Best Practice
Set AccessByPermission on the Role Center part, action, or field that should appear only for users with the permission, naming the table or object that the part actually depends on. The base application does this on its own Role Centers, for example AccessByPermission = TableData "Activities Cue" = I on the activities part of the Business Manager Role Center and TableData "Report Inbox" = IMD on the Report Inbox part (Control96) of the same Role Center and of the Accountant Role Center.
Two limits apply. The property takes effect only when the server's UI Elements Removal setting is LicenseFile or LicenseFileAndUserPermissions. It is UI removal, not a security boundary: the part's source data must still be protected by real permissions. When the condition is not a permission check, such as a setup value or a feature flag, AccessByPermission is the wrong tool. Put the condition inside the part page, which is a normal CardPart or ListPart that can have triggers. The part cannot remove itself from the Role Center, but it can hide or empty its own controls. See sample: rolecenter-permission-gating-must-use-accessbypermission.good.al.
Anti Pattern
A RoleCenter page, or a pageextension whose target is a Role Center, binds Visible or Enabled on a part, action, or field to a procedure call whose body checks ReadPermission, WritePermission, or a similar permission test, and declares that procedure. The compiler reports AL0573 and AL0569 as warnings, and both will become errors. Reviewer signal: a pageextension declares a procedure and AL0569 appears in its build output. The extended page's name is not reliable evidence of its type, so confirm the target is a Role Center from its PageType or from that diagnostic. Do not flag setup- or feature-based gating implemented inside the part page itself; that is the correct location for non-permission conditions. See sample: rolecenter-permission-gating-must-use-accessbypermission.bad.al.
References